Stop the water right now
- Turn the controller off and unplug it for one minute. If water stops, the controller or programming is the problem.
- If water keeps running, the valve is stuck open. Close the irrigation shut-off valve, usually near the backflow device or the water meter.
- Still running? Close the main shut-off at the meter box and call us at the number above.
What causes a zone to run nonstop
- A torn or debris-fouled valve diaphragm
- A manual bleed screw or lever left open
- A stuck solenoid plunger
- A controller with a failed station relay or a crossed wire
We isolate the cause, rebuild or replace the valve, test the controller output and make sure every zone shuts off cleanly. Running water can earn a Fort Worth water-waste violation, so we prioritize these calls.
Licensed & accountable: every repair is performed under Texas Licensed Irrigator — TCEQ License #LI0006529, with a written price before work begins.
Common questions
Why does one zone come on by itself?
Usually a valve that isn’t sealing or a controller relay that has failed. We test both to find out which.